Additional Infomation
| 7 inches colored touch screen |
| Password protected data login facility |
| Auto Gas Cutoff Facility |
| Auto Flame Failure Detection Facility |
| µP Based With Printer Interface |
| Five Element Measurement In Single Aspiration of the Sample |
| Curve Calibration Programmability using Maximum of 25 Standards |
| Data Processing Through Curve Fitting Techniques - Least Squares, Quadratic |
| Multiple Calibration Curves Saving Facility |
| Samples Data Storage Facility |
| Printer Attachment Facility |
| Measurement in ppm & meq |
| Useful For Both Medical & Soil Testing Applications |
| Setup Storage Facility up to 1 D setups files |
-
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 423
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 423
Warning: preg_match() expects parameter 2 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 252
Warning: strlen() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 324
| meq/I, 1 | 1 DD dil. |
| General Range : ppm meq/1 | |
| K | 0-100 |
| Ca | 0-100 |
| Li | 0-100 |
| Ba | 30-3000 |
| Urine Range | Na : 0-1 DD 0-200 meq/I, 1:1 DD dil. 0-250, K : 0-100 meq/I, 1:100 dil |
| Sensitivity | General Mode : Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca:15 ppm Ba 30ppm |
| Filters | Na & K Supplied (Ca, Li & Ba are optional at extra cost) {Factory Fitted Only} |
| Resolution | 0.1 ppm / 0.1 meq |
| Linearity | < 2% error when 3 ppm Na/K and 5 ppm Li are set as Maximum Std |
| Curve Fit Accuracy | ± 2% of FS |
| Display | Colored Touch Screen |
| Flame System | LPG & Dry Oil Free Air |
| Detector | Photodiode |
| Calibration | with up to 25 Standards of user choice with curve fitting software (5 for each Element). Multiple Calibration Curves can be stored in the memory |
| Aspiration Time | 3 ml per Minute |
| Dimensions | Instrument : 365 x 245 x 220 mm Approx. (LxBxH) |
| Power Supply | 230 V AC± 10%, 50 Hz |
-
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 423