Additional Infomation
23 to 2530 cfm (40 to 4300 m3/h) measuring range |
Simultaneously measures and displays airflow, temperature and humidity |
Displays the direction of the airflow as well as the velocity |
Removable handheld micromanometer with Bluetooth® wireless capability (Model 6715) |
Advanced storage feature allows you to store multiple measurements under a single ID# |
Lightweight design makes one-person setup and use easy |
Built-in back pressure compensation ensures accuracy for large volumetric flow measurements |
Temperature compensation sensor increases accuracy for all airflow measurements |
Full color display will tilt feature is visible at any angle |
Includes: Standard hood, carrying case, AA batteries, user manual, communication cable for PC, PC software and calibration certificate |
-
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 390
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 390
Warning: preg_match() expects parameter 2 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 252
Warning: strlen() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 324
HVAC testing, adjusting and balancing |
Air volumetric flow measurements through registers, diffusers and grilles |
Direct readout at supply and return airflow |
Air velocity measurement in the duct |
-
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 390
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 390
Warning: preg_match() expects parameter 2 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 252
Warning: strlen() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 324
Model | 6710 |
Airflow Range | 23 to 2530 cfm (40 to 4300 m3/h) |
Airflow Accuracy | +/- 3% of reading +/- 10 m3/h |
Airflow Resolution | 1 m3/h |
Air velocity Range | 0.15 to 40 m/s (with pitot tube) 0.15 to 15 m/s (with Velocity Matrix |
Air velocity Accuracy | +/- 3% of reading +/- 0.05m/s |
Air Velocity Resolution | 0.01 m/s (<9.99m/s), 0.12 m/s (>10.0m/s) |
Humidity Range | 0 to 100 %RH |
Temperature Range | -32 to 122°F (0 to 50°C) |
Temperature Accuracy | +/- 1.0°F (0.5°C) |
Temperature Resolution | 0.1°C |
Hood Dimensions | 2 x 2 ft (610 x 610 mm), 1 x 4 ft (305 x 1220 mm), 2 x 4 ft (610 x 1220 mm), 3 x 2 ft (915 x 610 mm), 3 x 3 ft (915 x 915 mm), 500 x 500 mm |
Dimensions | Meter unit: 3.4 x 7.4 x 1.6 inches (88 x 188 x 41 mm) |
Weight | 7.9 lbs (3.6 kg) |
-
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 390
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 390
Warning: preg_match() expects parameter 2 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 252
Warning: strlen() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 324
Datasheet | Download PDF |

India's First Pre and Post Aerosol Concentration Measuring Aerosol Photometer with Compliance to 21 CFR Part 11
Related Products
Handheld Particle Counter
Rated 0 out of 5
In stock
SKU:
687569