LPC-6CE
Description
The LPC-6CE is a high-precision liquid particle counter designed for accurate measurement of particle size and quantity in various types of injectable solutions, sterile powders, and pharmaceutical packaging materials.
20k products
24/7 Support
15+ Services
Recently Viewed Products
LPC-6CE
Rated 0 out of 5
Additional Infomation
| Meetthe 2020 editionofthe"ChinesePharmacopoeia"andcandirectlydetectthesizeand number of insoluble particles of injections, sterile powders and drug packaging materials (YBB00272004-2015). |
| Adopt high-performance imported laser light sources and compensation circuits to ensure the test accuracy of various colorless and colored samples, and can directly detect electrolyte-free samples. |
| Adopt imported high-pressure injection pump sampling system, which can set the injection volume according to the sample variety tested, with high injection accuracy, meeting the detection requirements of high-viscosity samples, and is not affected by factors such as geographical location, meeting the use requirements of different altitudes. |
| Theinjectionslitandpipelinearemadeofimported316LandimportedPTFEmaterials, which can directly detect special solutions such as organic solvents and oil matrices. |
| Accordingtothedemandofinjectionvolume,differenthigh-pressureinjectionsystemscan be replaced |
| Ithasalargeinfusiontestaccordingtothepharmacopoeiastandard,andthesampling volume and test times can be set arbitrarily |
| Ithasadrugpackagingmaterialtest,andthesamplingvolume,judgmentspecificationsand test times can be set arbitrarily |
| It has a special test program for small-volume injection (small injection), which can be injectedaccordingtothespecificationsofthesmallinjection,andautomaticallyconverted tothesizeandnumberofcontainerparticlesafterthetestiscompleted,whichmeetsthe requirements of the "Chinese Pharmacopoeia" and international general requirements |
| Color touch large screen operation: English interface switching, simple and fast operation, powerful functions. Can display multi-channel test data at the same time |
| It has sample name input and automatic storage, the number of sample name sis upto 1000 (expandable), and the operation is convenient and fast. |
| Datastorageupto1,000,000records,search,queryandprintthrough(samplename, sample batch number, test time, test account) |
| Equipped with a dot matrix printer to meet the long-term data storage. |
| Equippedwithhostcomputersoftware,RS232serialportdatatransmission,USBdatacopy |
| CanbeconnectedtoLIMESandothersoftwaremanagementplatforms,dedicateddata analysis software for data storage and statistics |
| With three-level password management authority. |
| Asinglemachinehas128operatorstomanage(expandable) |
| Canprovidestand-aloneversionof3Qcertificationdocumentsandinformation |
-
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 354
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 354
Warning: preg_match() expects parameter 2 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 252
Warning: strlen() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 324
| The intelligent particle detector is designed for the pharmaceutical, medical device and packaging material industries. It is suitable for particle contamination detection of injections, sterile powders, small-volume injections and other drugs, filtration rate verification of infusion equipment (such as anesthesia bags, precision filters), and compliance testing of drug packaging materials (glass bottles, rubber stoppers). It alsomeetsthehigh-precisiondatarequirementsoflaboratoryresearchanddevelopment, GMP production quality control and third-party testing agencies, and comprehensively protects drug safety and quality. |
-
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 354
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 354
Warning: preg_match() expects parameter 2 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 252
Warning: strlen() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 324
| Test range | 1~500μm |
| Full channel settings | ≥5μm, ≥8μm, ≥10μm, ≥12μm, ≥25μm, ≥100μm (channels can be customized according to user requirements) |
| Pharmacopoeia standards | ≥10μm,≥25μm, |
| Drug packaging material channel | ≥5μm, ≥10μm, ≥25μm, |
| Injection volume | ≥0.1ml or more any volume |
| Counting range | 0~9999999 particles |
| Detection particle concentration | 0~10000 particles/ml |
| Relative standard deviation RSD | ≤ 2% (standard particles ≥1000 particles/ml) |
| Channel resolution | ≥ 95% (≥10μm channel) |
| Sampling time | 5ml (<10seconds) 100ml (<3minutes) |
| Accuracy | Within±5%ofthespecifiedvalue |
| Output | USB,supportRS232,4-20mAcustomization |
| Stirring speed | 0~2000rpm |
| Working temperature | 0~40℃ |
| Working voltage | AC220V±10%; 50Hz≤90W |
| Instrument size | 420*350*470(mm) |
-
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 354
Warning: strpos() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/compat.php on line 354
Warning: preg_match() expects parameter 2 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 252
Warning: strlen() expects parameter 1 to be string, array given in /home/vmgsoftw/artinstruments.in/wp-includes/class-wp-block-parser.php on line 324
| Datasheet | Download PDF |